EcoShield system product sheet

80
100
60
40
20
0 4
C on
si st
en cy
, B c
Time, h 1 2 3
Conventional cement EcoShield system
Thickening Time
Slurry density
11.6
1,400
15.0 lbm/galUS
1,800 kg/m³
Bottomhole circulating temperature
120
48
180 degF
82 degC
Fluid loss
0 40 mL
Salinity
0 15% NaCl
slb.com/EcoShieldCopyright © 2023 SLB. All rights reserved. 23-WCFL-1612887
EcoShield Applications
→ Land operations
How it improves performance EcoShield™ geopolymer cement-free system provides an alternative to portland cement while delivering comparable performance.
EcoShield system matches the thickening time of conventional cement system.Operational range for EcoShield system.
Comparison of Rheological Parameters for 14.8 lbm/galUS EcoShield System with Similar Conventional Cement System
Parameter Conventional cement EcoShield system
Plastic viscosity, cP (Bingham) 36 35
Ty, lbf/100 ft2 (Bingham) 23 8
Ty, lbf/100 ft2 (Herschel-Bulkley) 9 8
Comparison of Compressive Strength for EcoShield System with Similar Conventional Cement System at 142 degF
Density—11.6 lbm/galUS Density—14.8 lbm/galUS
Conventional Cement Ecoshield System Conventional Cement Ecoshield System
Compressive strength–50 psi, h:min 8:45 8:27 1:42 1:45
Compressive strength–24 h, psi 480 240 2,180 1,060
Ultimate compressive strength, psi 500 750 3,000 3,500
All specifications are subject to change without notice.
Geopolymer cement-free system
How it works EcoShield system matches the rheology, thickening time, and compressive strength properties of portland cement-based systems. The technology fits within standard oilfield cementing workflows without major changes to the design process, onsite execution, or postjob evaluation.
http://www.slb.com/EcoShield